服務(wù)熱線
010-66039918
簡(jiǎn)要描述:美國(guó)熱電-賽默飛長(zhǎng)壽命石墨管 賽默飛Thermo 原子吸收光譜儀型號(hào):ICE3000 AAS原子吸收光譜儀、ICE3300AAS原子吸收光譜儀、ICE3400AAS原子吸收光譜儀、ICE3500AAS原子吸收光譜儀
美國(guó)熱電-賽默飛長(zhǎng)壽命石墨管美國(guó)熱電-賽默飛長(zhǎng)壽命石墨管
Thermo熱電原子吸收石墨管貨號(hào):942339395031
942339395031 Graphite Cuvettes, Ridged and Uncoated (10) 普通石墨管(10支/盒)
942339395071 Graphite Cuvettes, Ridged and Coated (10) 涂層石墨管(10支/盒)
942339395041 Extended Lifetime Cuvettes (10) 長(zhǎng)壽命石墨管(10支/盒)
942349020101 Omega ELC with Platform (10) Omega平臺(tái)石墨管(10支/盒)
942339395161 Graphite Contact Cones(Zeeman) 石墨錐 (對(duì))
942339395011 Graphite Contact Cones 石墨錐 (對(duì))
942339380031 小樣品杯 1000個(gè)/包
942339380021大樣品杯 50個(gè)/包
賽默飛Thermo 原子吸收光譜儀型號(hào):ICE3000 AAS原子吸收光譜儀、ICE3300AAS原子吸收光譜儀、ICE3400AAS原子吸收光譜儀、ICE3500AAS原子吸收光譜儀
<iframe allowfullscreen="" frameborder="0" height="498" mozallowfullscreen="" src="https://player.youku.com/embed/XNTEyNTMwMTkwOA" style="box-sizing:border-box;" webkitallowfullscreen="" width="510">iframe>
熱電石墨管使用注意:
1、 在安裝新的石墨管之前, 檢查接觸件的情況(電極)。經(jīng)過正常的工作運(yùn)行, 接觸件也會(huì)受到磨損。這樣的磨損會(huì)使管件在使用中松懈,從而導(dǎo)致因接觸不良而引起運(yùn)行和結(jié)果錯(cuò)誤。如果接觸件表面發(fā)生切削磨損,坑洼, 被灼燒, 或者其它磨損, 必須立即更換。運(yùn)行裝有破損接觸件的儀器會(huì)導(dǎo)致錯(cuò)誤的結(jié)果, 并且還會(huì)極大地降低管件的使用壽命。
2、在安裝過程中, 請(qǐng)使用干凈的塑料套(是PTFE)將管件從包裝箱中取出。千萬(wàn)不可用手來(lái)直接接觸管件! 否則將使管件受到污染, 并且很有可能使諸如鈣, 鈉, 和鉀元素的讀數(shù)結(jié)果上升。
3、使用合適的氣體和流速。過度降低運(yùn)行成本將會(huì)降低產(chǎn)品的使用壽命, 和增加產(chǎn)品受到污染的可能性。
4、 一旦管件安裝完畢, 在正式使用之前, 要根據(jù)儀器廠家提供的產(chǎn)品說(shuō)明書對(duì)管件預(yù)運(yùn)行一次。
5、 避免管件的過度加熱, 過度加熱將會(huì)嚴(yán)重地降低其使用壽命。
6、當(dāng)運(yùn)行從較低溫度轉(zhuǎn)向用于分析諸如Ni, Cr, V 或者Ti的較高溫度時(shí), 也許會(huì)發(fā)生由于冷的部件引起的暫時(shí)污染而導(dǎo)致的“記憶影響”。在這樣的情況下, 建議您在新的較高溫度之下, 先采用氣體流速對(duì)空白試劑運(yùn)行幾個(gè)循環(huán), 從而去除系統(tǒng)中的污染。
7、在管件接近使用壽命期*, 需注意適時(shí)更換。否則將會(huì)大大增加接觸件受到破壞的可能性。
8、使用硫酸將會(huì)極大地降低石墨管的使用壽命。
序號(hào) | 美國(guó)熱電 賽墨飛產(chǎn)品 |
1 | 1281340 ThermoFisher icap Q三通套裝 |
2 | 1301610 ThermoFisher 微流霧化器 |
3 | 1301660 ThermoFisher 進(jìn)樣泵管IRIS |
4 | 13017700 ThermoFisher 廢液泵管IRIS |
5 | 13017701 ThermoFisher iCAP Q工作線圈 |
6 | 1305260 ThermoFisher IcapQ2.5毫米中心管 |
7 | 1305600 ThermoFisher IcapQ2毫米中心管 |
8 | 1305640 ThermoFisher IcapQ1.5毫米中心管 |
9 | 1305650 ThermoFisher 進(jìn)樣蠕動(dòng)泵管 |
10 | 1305920 ThermoFisher PC3廢液管 |
11 | 1305940 ThermoFisher 石墨墊片-ICAP-Q |
12 | 1310900 ThermoFisher 截取錐-ICAP-Q |
13 | 1311870 ThermoFisher 旋流霧化室IcapQ |
14 | 1317080 ThermoFisher PFA霧化器IcapQ |
15 | 1317090 ThermoFisher IcapQ3.5嵌片 |
16 | 1318480 ThermoFisher ICAP Q泵油,一次一瓶 |
17 | 1319310 ThermoFisher icap Q內(nèi)標(biāo)管 |
18 | 1320040 ThermoFisher icap Q蠕動(dòng)泵管 |
19 | 1320050 ThermoFisher icap Q硅管 |
20 | 1320070 ThermoFisher icap Q硅管 |
21 | 1320080 ThermoFisher icap Q硅管 |
22 | 1320090 ThermoFisher icap Q硅管 |
23 | 1320100 ThermoFisher PFA霧化室IcapQ |
24 | 1320250 ThermoFisher PFA霧化室IcapQ |
25 | 1320260 ThermoFisher PFA適配器IcapQ |
26 | 1320270 ThermoFisher IcapQ鉑金2.0中心管 |
27 | 1321200 ThermoFisher IcapQ藍(lán)寶石中心管2.0 |
28 | 1323600 ThermoFisher IcapQ石英中心管2.0Laser |
29 | 1323630 ThermoFisher sensor板 |
30 | 13249702/3 ThermoFisher IcapQ蠕動(dòng)泵管 |
31 | 1329400 ThermoFisher 工具(調(diào)炬管準(zhǔn)直度) |
32 | 1330270 ThermoFisher 采樣錐-ICAP-Q |
33 | 1341420 ThermoFisher IcapQ鉑金采樣錐 |
34 | 1341430 ThermoFisher 耐氫氟酸1.5mm中心管 |
35 | 13643601 ThermoFisher iris中心管 |
36 | 13650201/2 ThermoFisher IRIS進(jìn)樣系統(tǒng) |
37 | 13683000 ThermoFisher 4V繼電器 |
38 | 13881000 ThermoFisher 4通道蠕動(dòng)泵 |
39 | 13891300 ThermoFisher IRIS普通霧化器 |
40 | 13918400 ThermoFisher 蠕動(dòng)泵 |
41 | 13931600 ThermoFisher 垂直霧化室IRIS |
如果您有任何問題,請(qǐng)跟我們聯(lián)系!
聯(lián)系我們
版權(quán)所有©2024 北京龍?zhí)祉w略科技有限公司 備案號(hào):京ICP備11018352號(hào)-1 sitemap.xml 技術(shù)支持:化工儀器網(wǎng) 管理登陸
北京龍?zhí)祉w略科技有限公司(kaixuanfood.com)主營(yíng):石墨管,石墨錐,空心陰極燈,元素?zé)?熒光燈,氘燈,鎢燈,矩管,中心管,霧化器,泵管,采樣錐,截取錐,樣品杯,標(biāo)準(zhǔn)溶液,原子吸收,原子熒光,光譜儀,質(zhì)譜儀
地址:北京市西城區(qū)西安門大街光明胡同23號(hào)院